Our Data Center

Data Center

Hosting in the US

WHERE WE HOUSE OUR INFRASTRUCTURE

Our Nobull Networks’ dedicated servers in the US are housed at our flagship facility in Federal Way, Washington. Located 25 miles south of Seattle, WA, the facility is situated outside liquefaction zones.

Liquefaction happens when loosely packed, waterlogged soil near the surface loses its strength in response to a natural disaster, like an earthquake. Such an event could impact our infrastructure, so we were keen to avoid areas where liquefaction was a risk.

When we were looking at hosting in the US, this facility stood out for us because of its superb location and its ability to withstand natural disasters. The short distance to Seattle also allows us access to the Seattle Internet Exchange (SIX), one of the largest peering exchanges in the US.

Keeping Our US Servers Safe

Our facility boasts a range of features designed to keep our US servers operational, whatever’s going on outside. All power to the facility comes from two separate providers, each with its own power grid. We also have three on-site generators with on-site fuel storage in case the grid power fails.

In addition, the facility features Uninterruptible Power Supply (UPS) systems with battery backup, giving you peace of mind knowing that our US servers are protected. Our facility is also equipped with a chilled water system with onsite water storage and redundant pumps, along with a dry pipe fire suppression system.

Datacenter Statistics

OBJECTIVELY FASCINATING

Here are just some of the features we have to keep our US servers safe and operational

  • Site recording and monitoring, 24 hours a day, seven days a week, 365 days a year

    1
  • Card-reader access control with swipe and PIN code requirement

    2
  • Video camera coverage with recording

    3
  • 14,065 sq. feet of raised flooring out of a total of 33,223 sq. feet

    4
  • Diverse and redundant fiber optic transit providers

    5
  • 480v 3-phase utility feeds - 8,000 amps (two total)

    6
  • Four UPS units - 750kVA each

    7
image
  • 8

    Battery room with 82 batteries for each UPS

  • 9

    Three Caterpillar diesel generators that work in ‘parallel’

  • 10

    Two 6,000-gallon diesel fuel tanks

  • 11

    Liebert PDUs in the data center

  • 12

    Advanced fire suppression and detection systems, including heat, smoke, pre-action sprinkler, and Inergen gas-tank system

  • 13

    Two Trane chillers and 12 50-ton chilled water CRAC units

  • 14

    Two 13,000-gallon backup water storage tanks